• Since 1956, Flamco has worked to develop, produce, and sell high-quality components for hydronic systems. Sustainable heating and cooling is an everyday life concern.
• Hydronic systems help reduce energy and emissions and therefore support sustainability in every step of the building life cycle.
• We pave the way for sustainable heating and cooling for eco-friendly residential, commercial, and industrial buildings through innovative products like magnetic air & dirt separators, expansion vessels, and vacuum deaerators.
Working
• Pressure Maintenance: The pressurization unit ensures the system maintains a constant pressure by adding or removing air or water as needed to accommodate changes in volume due to temperature fluctuations.
• Integration with Expansion Tank: The expansion tank absorbs excess pressure from the heating or cooling system as the water expands when heated and contracts when cooled, preventing pressure spikes.
• Water Management: The pressurization unit controls the air volume in the expansion tank to maintain optimal pressure levels, ensuring the HVAC system operates efficiently and safely.
• Pressure Sensors and Control: Sensors monitor system pressure continuously, and the control system adjusts the pressurization unit’s operation to maintain the desired pressure within the HVAC system.
• Preventing Water Hammer and System Stress: By maintaining consistent pressure and using the expansion tank to manage volume changes, the pressurization unit helps prevent water hammer (sudden pressure spikes) and reduces stress on pipes and other system components.
Working
• Pressure Maintenance: The pressurization unit ensures the system maintains a constant pressure by adding or removing air or water as needed to accommodate changes in volume due to temperature fluctuations.
• Integration with Expansion Tank: The expansion tank absorbs excess pressure from the heating or cooling system as the water expands when heated and contracts when cooled, preventing pressure spikes.
• Water Management: The pressurization unit controls the air volume in the expansion tank to maintain optimal pressure levels, ensuring the HVAC system operates efficiently and safely.
• Pressure Sensors and Control: Sensors monitor system pressure continuously, and the control system adjusts the pressurization unit’s operation to maintain the desired pressure within the HVAC system.
• Preventing Water Hammer and System Stress: By maintaining consistent pressure and using the expansion tank to manage volume changes, the pressurization unit helps prevent water hammer (sudden pressure spikes) and reduces stress on pipes and other system components.
Product Features
- For system volumes up to 300,000
- Break Tank: 18 litre break tank with type AB Air Gap Fluid Cat 5 (Midifill Plus: 4 litre).
- System quick-fill
- Password protection for parameter
- Pressure settings in 1 bar increments.
- Service reminder option (12 months).
- Pump pulse option (2 second pulse if inactive for 60 days).
- Flood protection
- Event logging for pump start, individual pump run hours counter, electrical interruption and common
- Volt free contacts for common fault, high pressure, low pressure, pump fault, pressure transducer (Top-up controller only).
- Individual controllers for pressurisation and degassing
- Vacuum degassing, turbo and normal interval
- Electric pump, 230V 50Hz 1ph (2160D: 415V 50Hz 3ph).
Salient Features
• The Flamco compact wall mounted and free standing pressurization units are fully automatic heating / chiller system top-up devices, offering accurate control and reliability.
• A precise pressure monitoring within +/- 0.2 bar
• They are suitable for pressure management in domestic, commercial and industrial sealed heating and cooling systems.
• A choice of single or twin pump system for topping up water using a break-tank and a digital controller.
• An AB type break tank for back flow protection.
Applications:
Metro Station
An Flamco- Pressurization Unit in an HVAC system in a metro station manages pressure changes, ensuring consistent climate control and preventing damage to the system.
Offices
Maintains stable water pressure for HVAC systems, ensuring comfort and efficiency.
IT Park
An Flamco- Pressurization Unit in an HVAC system in an IT park stabilizes pressure, ensuring reliable cooling for critical IT infrastructure and preventing system failures.
Colleges
Supports consistent water pressure in classrooms, laboratories, and dormitories.
Hospitals
Maintain critical temperature control in patient rooms, operating theaters, and other medical facilities.
Hotels
Provides consistent water pressure in guest rooms, enhancing guest satisfaction.
Goverment Departments
An Flamco- Pressurization Unit in a government building prevents pressure buildup in the heating and cooling systems, protecting infrastructure and ensuring consistent system performance.
Data Centre
An Flamco- Pressurization Unit in a data center building helps manage pressure fluctuations in the cooling system, ensuring stable operation and preventing damage to equipment.
Commercial Buliding
An Flamco- Pressurization Unit in an HVAC system in a commercial building maintains pressure balance, preventing system stress and prolonging the lifespan of the equipment.
Industrial Bulidings
An Flamco- Pressurization Unit in an HVAC system in an industrial building absorbs pressure fluctuations, safeguarding equipment and ensuring efficient, uninterrupted operation.