Active Indoor Air Purification and Disinfection Solutions

One Stop DBD Bi Polar Ionization (BPI) Solution for Indoor Air Quality Improvement and Monitoring meeting Industries highest standards –Proven reductions in VOCs, odors, PMs and tested and proven against COVID and other Viruses, Bacterias, Fungus, Molds and Pathogens. AtmosAir, USA

Expansion, Pressurization, deaeration & Top up

Precise pressure control ±0.2 bar c/w vacuum degassing/pall rings and top up, state of the art micro-electronics a/w weight sensor, pressure sensors etc. integrated with SPC display, control panel and duly internally piped ready to connect factory assembled Cabinet/Skid Mounted unit. (Replaces Conventional Expansion tank, pressurization unit & air separator –3 in 1 unit): Flamco, Holland/Europe

Side Stream Filtration

Deals with suspended Solids in Condenser water Cooling Tower System, removes particulate matter above 40 microns, improves condenser approach and enhances Chiller IKW, Helps Condenser System and equipment to operate at designed efficiency (Replaces obsolete barrier filtration Technologies): Lakos, USA

Grooved piping system (Replacement of Welding)

A mechanical bolted coupling that would engage into grooves and use a gasket seal. Complete grooved solutions: What began as simply a faster, easier and more economical way of joining pipe has evolved into a whole new approach of solving piping problems – a ‘total’ systems approach. Victaulic grooved end products comprise of rigid and flexible coupling, accessories, valves, fittings and adaptors and gaskets Victaulic, USA

Non-Chemical Cooling Tower Water Treatment System

Deals with dissolved solids in water, it removes scale, corrosion & bio fouling in condenser water system without using any chemical an also saves blow down water by increasing cycle of concentrations (Replacement of Chemical dosing): Elgressy, Israel

Thermal Storage

Ice on Coil Latent Storage system (Off-Peak Cooling System, Tesla of Air-conditioning, downsizes the connected Load, sustainable, energy saving technology) Calmac USA b. Stratified Sensible CHW Storage system for Data Centres, Critical Missions Facilities, District Cooling Applications

Non-Powered Automatic Tube Cleaning System

Non-powered solution using the existing condenser flow utilizing Dual Loop Design system restricting the mixing of CDW In and Out water with negligible head loss and no wastage of balls. Hydroball, Singapore

Solar Cooling solution

At Purix we believe the use of air condition should be a pleasant and environmentally friendly experience. Our response is a solar air condition product made for people, powered by the sun. Purix assists you in responding to global environmental challenges at the local level by supplying attractive solar air conditioning units. Solar heat and pure water are the essential active ingredients to make your environment comfortable. In addition to providing an agreeable indoor climate, getting cooled by the sun is sustainable and reduces costs and climate emissions. Purix, Denmark

Active Indoor Air Purification and Disinfection Solutions

One Stop DBD Bi Polar Ionization (BPI) Solution for Indoor Air Quality Improvement and Monitoring meeting Industries highest standards –Proven reductions in VOCs, odors, PMs and tested and proven against COVID and other Viruses, Bacterias, Fungus, Molds and Pathogens. AtmosAir, USA

Expansion, Pressurization, deaeration & Top up

Precise pressure control ±0.2 bar c/w vacuum degassing/pall rings and top up, state of the art micro-electronics a/w weight sensor, pressure sensors etc. integrated with SPC display, control panel and duly internally piped ready to connect factory assembled Cabinet/Skid Mounted unit.

Side Stream Filtration

Deals with suspended Solids in Condenser water Cooling Tower System, removes particulate matter above 40 microns, improves condenser approach and enhances Chiller IKW, Helps Condenser System and equipment to operate at designed efficiency (Replaces obsolete barrier filtration Technologies): Lakos, USA

Grooved piping system (Replacement of Welding)

A mechanical bolted coupling that would engage into grooves and use a gasket seal. Complete grooved solutions: What began as simply a faster, easier and more economical way of joining pipe has evolved into a whole new approach of solving piping problems – a ‘total’ systems approach.

Non-Chemical Cooling Tower Water Treatment System

Deals with dissolved solids in water, it removes scale, corrosion & bio fouling in condenser water system without using any chemical an also saves blow down water by increasing cycle of concentrations (Replacement of Chemical dosing): Elgressy, Israel

Thermal Storage

ce on Coil Latent Storage system (Off-Peak Cooling System, Tesla of Air-conditioning, downsizes the connected Load, sustainable, energy saving technology) Calmac USA b. Stratified Sensible CHW Storage system for Data Centres, Critical Missions Facilities, District Cooling Applications

Non-Powered Automatic Tube Cleaning System

Non-powered solution using the existing condenser flow utilizing Dual Loop Design system restricting the mixing of CDW In and Out water with negligible head loss and no wastage of balls. Hydroball, Singapore

Solar Cooling solution

At Purix we believe the use of air condition should be a pleasant and environmentally friendly experience. Our response is a solar air condition product made for people, powered by the sun. Purix assists you in responding to global environmental challenges at the local level by supplying attractive solar air conditioning units.